Location -> Products -> Level -> Level Switch

Type:CX-FLM-UQK-71 anti-corrosive Float level controller
Illustrate: The sensor arrange in a group of reed switch ,the reed switch will have the relative action and the resistance will change when the float with magnet drift up and down .
Anti-corrosive Float level controller
The sensor arrange in a group of reed switch ,the reed switch will have the relative action and the
resistance will change when the float with magnet drift up and down .The instrument panel respond
to the level height and produce the figure change . The switch of level control height on the panel ,
which can set it in any control range randomly . When the level reach the given height ,the display
instrument emit contact signal and alarm .
Main parameter:
1,Sensor
Sensor material | Medium pressure(Mpa) | Temperature℃ | Range H(mm) |
1Cr18NiTi(G) (GX) | 2.5,1.6,0.6,0.25 | -40~150 | 0~12m |
F46(F) | 2.5,1.6,0.6,0.25 | -40~150 | 0~12m (select randomly) |
P.V.C(S) | 0.6,0.25 | -40~150 | 0~6m (select randomly) |
Medium density:≤0.45g/cm3
Medium Viscosity:≤1st[(1/10000)m2/S]
Flange standard:JB/T82-1-94 Dn150 PN2.5,1.6,0.60,0.25MPa(G x type is DN40) ,other standard like GJ,GB,ANSI etc.
User and design apartment ,please notice the anti-explosion mark;Anti-explosion type d II BT5,Basic type ibCT1~6
2,Display instrument
Function | Display 2-point | Display 4-poin | Display 10-poin | Display 50-poin | 100D | Digital display |
Alarm | Sound and light | Sound and light | Light | Light | Light | Light |
Control | / | / | Random | Random | Random | Random |
Power and contact capacity:220VAC 0.5A
Power consumption:6W
Display color:Liquid range in green ,alarm in red
Electric connection :Female screw M20 x 1.5
Dimension:80×160×200mm
Type: CX-FLM-UQK-71
Anti-explosion class dIIBT4,Other parameters are the same as the ordinary series meter .
Last:CX-ULM-UQK-91 float leve.. Next:CX-UQK float level sensor