精品视频无码一区二区三区,亚洲精品中文无码AV在线播放,蜜臀av无码精品人妻色欲,青娱乐国产盛宴免费青娱乐,久久久久精品午夜理论片欧美

sales@gninstruments.com

Type:CX-ICM-1101 industrial conductivity meter

Illustrate:Widely used for continuous monitoring of the conductivities of solutions used in the following fields: thermal power plant, chemical fertilizer, chemical industry, metallurgy, environmental protection, pharmacy manufacturing, biochemistry, foodstuff and running water.

CX-ICM-1101 industrial conductivity meter

Brief Introduction
1.It is our company’s latest top-class instrument equipped with a microprocessor
2.It is characterized by its intelligent operation, multi-function and high measuring performance and its strong environmental adaptability
 
Main Features
1.Display:conductivity, output current, temperature, time and status.
2.Bitmap type liquid crystal display modulewith high resolution is adopted.
3.Thereis no symbol or code that is defined by the manufacturer.
 
Main Parameters

Measuring range 0.01~20μS/cm(Electrode:K=0.01),00.1~200μS/cm
(Electrode: K=0.1)
1.0~2000μS/cm(Electrode:K=1.0),10~20000μS/cm
(Electrode:K=10.0)                       
30~600.0mS/cm  (Electrode: K=30.0)
Intrinsic error of the electronic unit 2. : conductivity: ±0.5%FS, temperature: ±0.30C
Automatic temperature compensation 0~99.9C, with 25C as the reference temperature
Water sample tested 0~99.9C, 0.6MPa
Intrinsic error of the instrument Conductivity: ±1.0%FS, temperature: ±0.5C
Automatic temperature compensation error ±0.5%FS
Repeatability error ±0.2%FS±1 Unit
Stability ±0.2%FS±1 unit/24h
Isolated current output 0~10mA ( load<1.5kΩ),4~20mA (load<750Ω)
Output current error ≤±l%FS
Error caused by ambient temperature ≤±0.5%FS
Error caused by the supply voltage  ≤±0.3%FS
Alarm relay  AC 220V, 3A
Communication interface RS485 or 232 (optional)
Power supply AC 220V±22V, 50Hz±1Hz
Protection grade IP65
Clock accuracy ±1 minute/month
Data storage capacity l month (1 point/5 minutes)
The time for Saving data 10 years
Overall dimension 146 (length) x 146 (width) x 108 (depth) mm;
Dimension of the hole 138 x 138mm
Working conditions ambient temperature0~60C; relative humidity <85%
Note: The conductivity electrodes with the following five constants are usable: K=0.01, 0.1, 1.0, 10.0, and 30.0.

Last:CX-ICM-1101A industrial conduct.. Next:CX-ICM-1104 industrial conducti..

Contact Us

Office Address: Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)

Phone:021-57635022

E-mail:info@gnflowmeter.com

E-mail:sales@gninstruments.com

關(guān)閉
精品视频无码一区二区三区,亚洲精品中文无码AV在线播放,蜜臀av无码精品人妻色欲,青娱乐国产盛宴免费青娱乐,久久久久精品午夜理论片欧美